If there is a change to LINCSUPPORT, the system must be disabled for the duration of the first deployment. This prevents duplicate LINCSUPPORT libraries in the mix for the application, which causes the system to hang.
After an IC has been installed, the first system deployment will check for a change to LINCSUPPORT and check whether the application is active. If there is a change to LINCSUPPORT and the application is active, the deployment will advise the user that the application must be disabled for the duration of the rest of the deployment. The deployment will not continue until the application has been disabled.
The following messages appear in the Build Log for a build or the Sumlog for a transfer:
“New LINCSUPPORT installed, you must disable your system to continue the deployment.”
“PROGRAMMATICALLY SUSPENDED”
“<database> CONTROL FILE IN USE – WHEN DB CLOSED, OK TO CONTINUE”
Action required:
Disable the system.
Respond to the waiting entry.