Configure Options Screen

Use the Configure Options screen to provide general details about the configure. This screen is displayed when you initiate the SMU.

Retain Existing Database

If you are transferring a standard (primary) application, this property must contain either Y or N. If you are transferring a standby application to support a secondary database or Reports to inquire against a remote database, enter R or S.

For a Standard Application

Enter N to set up a new (empty) database (the existing database is cleared by DMS II initialize).

Enter Y to retain the database already on the target host (the database definition is altered to that on the transfer medium). You can enter Y only when any of the following conditions are true:

Note: If your transfer medium contains database data, entering Y replaces any existing data in the Runtime database.

For a Remote/Secondary Application

If you are configuring an optional standby System to support a secondary database, enter S or R. In either case, the database itself is not configured (or reorganized), as this has been performed by the Remote Database Backup clone procedure from the Database Operations Centre.

If you are transferring Reports only (for inquiry-only use against a Remote database):

Application Name

Enter the name of your application. If you entered Y in the Retain Existing Database property, you must use the existing application name.

Database Name

Enter the name of your Runtime database. If you entered Y in the Retain Existing Database property, you must use the existing Runtime database name.

Configure as Usercode / Password

Enter the usercode and password under which your configured database and system programs are to run. All database files, programs, and all tailored DMS II software run under this usercode.

The defaults are the usercode and password under which your Configure Utility is running.

About Usercodes

Accesscode / Password

Enter the accesscode for your System usercode if required.

Chargecode

Enter the chargecode for your System usercode if required.

Window

Enter the window name to be defined to COMS for your application. (This is the window name that users of your application sign on to.) This name is also used as the COMS DATABASE name.

Language

Enter the language that you want to be used with the application being configured. By default, it is ENGLISH.

Configure Job

Enter the WFL job that is included on the tape to carry out all the tasks for your actual configuration. This property is preset to the following value:

NGEN28/WFL/CONF

Once you have transmitted your completed parameter screens, the file you name is copied from your Transfer tape by the SMU, and the WFL job is started.

Media Type

Enter the type of media, either TAPE or DISK, which contains the files to be copied.

Configure Tape

Enter the name of the Transfer tape (or pack name if the transfer is from a pack) that contains all the files that are to be copied.