Roll Back Function Fails in Fabric Manager User Interface and s-Par

Symptoms

If the commissioning of a partition image is unsuccessful, the Roll Back function of the Fabric Manager user interface and s-Par® may also fail. The Roll Back function can

  • Fail in both s-Par® and Fabric Manager

  • Fail in s-Par® but succeed in Fabric Manager

  • Fail in Fabric Manager but succeed in s-Par®

This is indicated in the event console of the Fabric Manager user interface. The state of the partition image is displayed as Unknown or Inactive.

Impact

All the s-Par® resources such as LUNs, chassis, and LAN subnets that are used by the failed partition image are blocked and cannot be used for commissioning another partition image. Also, the images and blueprints associated with the failed partition image cannot be deleted.

Solutions

  1. Identify the s-Par® IP address. For more information, see Identifying the s-Par® IP Address.

  2. Determine the UUID. For more information, see Determining the Universal Unique Identifier (UUID) of a Partition Image.

  3. Perform one of the following: