LOGANALYZER uses the system libraries JOBFORMATTER and SDASUPPORT. These libraries must be present as support libraries that appear in the SL (Support Library) system command display.
On systems with the Secure Access Control Module or Secure Accountability Facility, the SDASUPPORT library is used as a filter on the analyzed SUMLOG records. Refer to the USERCODE option for a description of the SDASUPPORT filtering procedure.
Additional system libraries are required for analysis of certain log entry types. The following are these libraries, which should be defined by the SL system command:
-
The CNSTRANSLATION library is necessary for analysis of log entries for some networking protocols..
-
The HWERRORSUPPORT library is necessary for complete analysis of Major Type 2, Minor Type 23 (Mainframe Hardware Report) entries. If this library is not available, LOGANALYZER performs a partial analysis of these log entries.
-
The SITESUPPORT library is necessary for analysis of Major Type 7 (Installation) entries. It can also be used for customizing log reports. If this library is not available, LOGANALYZER generates a HEX dump of the SUMLOG entry for Major Type 7 or performs the standard formatting of the SUMLOG entries for any other Major Type.
-