DC (Data Communications)

The DC command prints a full data communications analysis.

Syntax

── DC ─┬───────────────┬───────────────────────────────────────────────┤
       └─ NSP ─┬───────┤
               └─ MSG ─┘

Explanation

The following text describes the meaning of each option.

DC

Prints a full data communications analysis.

DC NSP

In addition to a full data communications analysis, prints an analysis of the network support processor (NSP) tables. This analysis includes NSP line vectors, NSP line tables, and NSP station tables in addition to the data communications controller (DCC) table analysis.

DC NSP MSG

In addition to a full data communications analysis, analyzes messages in nontanked data comm queues in the DCALGOL queue.

Example

The following example shows output from the DC command.

INPUT: DC NSP MSG
Data Communications Analysis
LSN Ranges:
    Maximum Datacom LSN = 00316  Minimum LSN = 00002
    Maximum MCP LSN     = 16483  Minimum LSN = 16384
NSP Datacom Configuration:
    Configured : Relative NSP Number(s) = 2, 4
    Initialized: Relative NSP Number(s) = 2
    NSP0112/02 : Unit Taken, Max Lines=15, DCC SNR=090
MCS Information:
    MCS[1]:  SYSTEM/CANDE
              RSN Field Size = 14, Stack = 070,
                                        Primary Queue = 0016
    MCS[2]:  SYSTEM/COMS
              Expanded Capacity, RSN Field Size = 12,
                           Stack = 076, Primary Queue = 000B
    MCS[3]:  SYSTEM/RJE
              Not Running, No Primary Queue
    MCS[4]:  SYSTEM/X25
              Not Running, No Primary Queue
    MCS[5]:  SYSTEM/DIAGNOSTICMCS
              Not Running, No Primary Queue
    MCS[6]:  SYSTEM/RJEBSC
              Not Running, No Primary Queue
    MCS[7]:  SYSTEM/BNAMCS
              Not Running, No Primary Queue
    MCS[8]:  SYSTEM/COMS/ENTRY
              Not Running, No Primary Queue
    MCS[9]:  SYSTEM/STATION/TRANSFER
              RSN Field Size = 14, Stack = 15B,
                                        Primary Queue = 0063
    MCS[10]: SYSTEM/COMS/KERNEL
              Not Running, No Primary Queue
    MCS[11]: COMS/ODT/DRIVER
              Not Running, No Primary Queue
    MCS[12]: GEMCOS/MCS
              Not Running, No Primary Queue
    MCS[13]: SYSTEM/ASSISTANT
              Not Running, No Primary Queue
    MCS[14]: SYSTEM/MHS/MSL
              Not Running, No Primary Queue
    MCS[15]: SYSTEM/APL
              Not Running, No Primary Queue
    MCS[16]: *SYSTEM/APT ON MCPMAST
              Not Running, No Primary Queue
    MCS[17]: *SYSTEM/ASSURE ON MCPMAST
              Not Running, No Primary Queue
    MCS[18]: SYSTEM/AFFIRMIT ON MCPMAST
              Not Running, No Primary Queue
    MCS[19]: *SYSTEM/CCE/ASODT ON PACK
              Not Running, No Primary Queue
    MCS[20]: SYSTEM/TELNET
              RSN Field Size = 14, Stack = 0C4,
                                        Primary Queue = 001A


DCC Station Table
LSN 2: DLS=2:0:0
          0 5A0080 026050  (WrapAround, Enabled, Not/Ready,
                                Not/Attached, Reconfiguring,
                                  MCS=2, MyUse=IO, Width=80)
          0 6F010A 640001  (ControlChar=4"6F", RemoteType=1,
                                    Retry=10, Frequency=100,
                                                NIF Index=1)
          0 000000 000000  (PseudoMCS=0)
          0 000000 820000  (DLS=2:0:0)
          0 000000 000000  (DCCSTAQUEUES [2]: Primary=None,
                                    Current=None, File=None)


LSN 3: ----- No Line Assignment -----
          0 500140 036050  (WrapAround, Enabled, Ready,
                              Not/Attached, MCS=5, MyUse=IO,
                                                   Width=80)
          0 6F010A 640002  (ControlChar=4"6F", RemoteType=1,
                                    Retry=10, Frequency=100,
                                                NIF Index=2)
          0 000000 000000  (PseudoMCS=0)
          0 000000 000000  (DLS=None)
          0 000000 000000  (DCCSTAQUEUES [3]: Primary=None,
                                    Current=None, File=None)
  .

  .

  .

DCC Line Table For Relative NSP Number 02   NSP0112/02
Line 0: (Relative LSP Number=0:0, Descriptor Address=66202)
          0 000107 500037  Line Descriptor:  Line #1,
                                       LSP 117, Index=00037
          0 800001 010006  (Max Stations=1, Real Stations=1,
                                               NIF Index=6)
          0 000000 000008  Station 0:  LSN=2

Line 1: (Relative LSP Number=0:1, Descriptor Address=66203)
          0 000000 000000  Line Descriptor
          0 000000 000000  ***** Invalid Line *****
  .

  .

  .

NSP Table Analysis For NSP 2
=== ===== ======== === === =

NSPSTATUS 2:0 00700F C00090  Max Lines=15, Unit=112,
                                  Unit Taken, DCC SNR = 090
  NSPMASTER 2: 5 800001 0025E0    (Data Desc To Line Vector)
  Line 0 Desc  : 0 000300 000048    (Algorithm # 3)
        Line Word 0: 0 000001 000000    (Ready)
                                        (Line Tog[1]=FALSE,
                                          Line Tog[0]=FALSE,
                                             Max Stations=1)
                                        (Line Tally[1]=0,
                                            Line Tally[0]=0)
        Line Word 1: 0 000000 000000
        Sta 0 Desc : 0 640000 600010  (Enabled, Not Ready)
              Station Word 0: 0 6F0D16 072D01
                                         (ControlChar=4"6F",
                                                  EXT=4"0D",
                                            BackSpace=4"16",
                                                  WRU=4"2D",
                                          Application=4"01")
              Station Word 1: 0 001794 001794
                                  (Station Queue Head=01794,
                                   Station Queue Tail=01794)
              Station Word 2: 0 000000 000000
              Station Word 3: 0 000000 000000
              Station Word 4: 0 000000 000000
              Station Word 5: 0 000000 000000
              Station Word 6: 0 000000 030000
                                          (Output Limit = 3,
                                                Pending = 0)
              Station Word 7: 0 000000 000000

Line 1 Desc  : 0 000000 200000
                *************** Invalid Line ***************
    .

    .

    .
READY: